Search This Blog

2023/02/12

NGL Fractionation 2


Feed part2

Feed Characteristics Pressure (kPa) 5000 Temperature 25 (°C) Molar Flow (kgmol/hr) 2988 Feed Composition Nitrogen 1.49E-02 CO2 2.00E-03 Methane 0.9122 Ethane 4.96E-02 Propane 1.48E-02 i-Butane  2.60E-03 n-butane 2.00E-03 i-pentane 1.00E-03 6.00E-04
 n-pentane 3.00E-04 n-hexane.

DISTILLATION COLUMN SPECS
CONDENSER
FULL REFLUX
5 No of STAGES

COLUMN DUTY 0.001kJ/hr
200 psia (liquid
Reid Vapor Pressure phase)
CONDENSER
PRESSURE
2766 (kPa)
REBOILER
PRESSURE
2800 (kPa)
VALVE SPEC
dp 2165 (kPa)

this simulation part 2 for that is link 

https://hysys-program.blogspot.com/2023/02/ngl-fractiontion.html









 

2023/02/07

NGL Fractiontion


Feed part1

Feed Characteristics Pressure (kPa) 5000 Temperature 25 (°C) Molar Flow (kgmol/hr) 2988 Feed Composition Nitrogen 1.49E-02 CO2 2.00E-03 Methane 0.9122 Ethane 4.96E-02 Propane 1.48E-02 i-Butane  2.60E-03 n-butane 2.00E-03 i-pentane 1.00E-03 6.00E-04
 n-pentane 3.00E-04 n-hexane.


SIMULATION DATA

Property Package: Peng-Robinson.

COOLER SPECIFICATIONS

COOLER 100 OUTLET
TEMPERATURE -62 (°C)

 dp (kPa)20

COOLER 101
OUTLET TEMPERATURE(°C)25

dp (kPa) 15

part 2 link
https://hysys-program.blogspot.com/2023/02/ngl-fractionation-2.html 







 

2023/02/02

Crude Oil Pre Heat simulation



Problem Statement Cont.


A crude stream at 15°C, 1000 kPa and flowrate of 6x105 kg/hr is

 mixed with a stream of water at 15°C, 1000 kPa and flowrate of

 21600 kg/hr using a Mixer, the outlet from the mixer is then

heated to 65°C through a Heater (Ap=50 kPa),the heater outlet is

 feed to the tube side of a Shell & Tube Heat Exchanger, where it's

 heated using a Shell inlet stream having the same composition as the

 crude feed stream and enters the shell of the heat exchanger at

 180°C, 200 kPa and flowrate of 175m³/hr.





The liquid product from the separator is then heated to 
400°C inside a Heater (Pressure drop-250 kPa) before entering the Atmospheric Column.

Heat Exchanger Specification:
Use Simple weighted model

- The Shell side outlet Temperature is 95°C

Calculate:

-The vapor fraction of the product stream before
entering the atmospheric column.

Min Approach; This is the minimum temperature difference between

 the hot and the cold stream. The vapor molar flow rate from the 
 Pre-Flash.

The pressure drops for the Tube and Shell sides, will be 35 kPa and 5

 kPa, respectively. The tube outlet from the Heat Exchanger is

then sent to a desalter which is simply modeled as Three Phase

 Separator where desalted water, oil and gas is separated.

The oil stream (light liquid) from the desalter is then heated to 175°C

 through a Heater (Pressure drop=375 kPa) and then sent to a Pre

 flash (Separator) to reduce the light components in the feed.

See the part1 &2 simulation


Part 1



Part2






 

NGL Fractionation 2

Feed part2 Feed Characteristics Pressure (kPa) 5000 Temperature 25 (°C) Molar Flow (kgmol/hr) 2988 Feed Composition Nitrogen 1.49E-02 CO2 2....