Search This Blog
2021/11/26
OIL AND GAS SEPARATION
Learning objective
How to conceptual design builder to process the gas oil separation from an oil field
l
2021/11/25
Reactive Distillation in DWSIM
Learning Objective
• How to setup chemical reaction kinetics in distillation column.• How to specify reaction chamber inside distillation column.• How to recover unreacted reactant and recycle it.• How to use pump and valve unit operations
Basic Information
It integrates chemical reaction and distillation in a single apparatus. (reversible,
liquid phase reactions)Removing one or more of the products is one of the principles behind
reactive distillation>reduced capital investment>significant energy savings>surpass equilibrium limitations>simplify complex processes>Increase product selectivity
>improve separation efficiency
SEE SIMUALTION
2021/11/23
Relief Valve Sizing
Learning Objectives
How to set up a pressure safety valve in HYSYS
SEE SIMULATION
Distillation Column Internals
Learning objectives
• How to Design the distillation column internal
. Flooding and weeping concepts
Flooding
• Excessive liquid build-up in column leads to flooding condition.
• Liquid cant get down the column due to high vapor velocity.
• It sets the upper limit of vapor velocity for steady State column operation
Weeping
• At low vapor flow rates, liquid starts to leak from the plate holes.
• When none of the liquid reaches to downcomers at extreme weeping
condition at very low vapor flow, is called dumping
see simulation
2021/11/22
HYSYS,VACUUM DISTILLATION/ PART4
Learning objectives
How to simulate vacuum distillation column to treat atmospheric
unit residue
Problem Statement
Additional steam is injected into the Vacuum Feed Heater to increase
velocity & minimize coke formation within the heater
2021/11/21
HYSYS, Debutanizer Simulation part3
learning Objective Part 3
How to simulation debutanizer column to stabilize the Naphtha and to recover LPG
ALL DATA IN YOU ARE NDD IN SIMULATION
PART3 SIMULATION
2021/11/19
HYSYS. Atmospheric Crude Distillation Part2
Learning objectives
Simulation of atmospheric distillation column
How to setup crude distillation unit with three side strippers
and three pump arounds in HYSYS
part2
Subscribe to:
Posts (Atom)
NGL Fractionation 2
Feed part2 Feed Characteristics Pressure (kPa) 5000 Temperature 25 (°C) Molar Flow (kgmol/hr) 2988 Feed Composition Nitrogen 1.49E-02 CO2 2....
-
Physical Properties: Fluid Package .Property Package Selection - .Plenty of packages - . Each has its specification- .Typ...
-
Design of Heat Exchanger V10 An example: Design an exchanger to sub-cool condensate from a methanol condenser from 95°C to 40°C....
-
Design a shell and tube see the simulation design shell and tube using kerosene 42 API and crude oil 34 API The problem : Design a she...